After cleaning, place the backer rod in the sawed joints, then immediately seal the joints with hot-poured sealant applied through a nozzle projected into the sawed joint, filling from the bottom up. Ensure that the seal completely fills the joint such that after cooling, the level of the seal is not greater than 1/8 inch (3 mm) below the ...
Closed cell backer rod should be about 1⁄8″ (3 mm) larger in diameter than the width of the joint to allow for compression. Soft backer rod should be approximately 25% larger in diameter than the joint width. The sealant does not adhere to it, and no separate bond breaker is …
Since 1984, Specialty Construction Supply is the most comprehensive source of road construction and paving products in the Northwest. From asphalt sealers to safety systems, we provide you with convenient access to an exhaustive inventory of materials and equipment.
Backer Rod is available in two basic forms: Closed-Cell and Open-Cell. Closed-Cell: For joints susceptible to the presence of moisture prior to joint sealing such as horizontal joints. Standard Backer Rod - suitable for glazing installations, window & door …
Crack-Stix ® 125ft. MEDIUM 1/2″ Black Permanent Asphalt Crack Filler is the only PERMANENT, patented solution to blacktop or concrete cracks on the marketplace.It is the same product seen on highways and roads but the only difference is YOU CAN APPLY IT …
If there is a deep crack, it should first be filled with a backer rod. The ideal depth of the repair material should not be more than twice the width of the crack.
Amazon: Pre-Caulking Filler Rope Backer Rod Roll, 100' Length x 1/4" Width, Grey, 1/4" x 100' : Everything Else
CERA-ROD™ NON-GASSING, HEAT-RESISTANT BACKER ROD DESCRIPTION CERA-ROD is a round, flexible, continuous-length, non-absorbent, non-gassing, non-staining, and non-shrinking material extruded from a cross-
A backer rod fills a wide gap between surfaces to allow you to more easily fill the gap with caulk. Commonly, you use a backer rod to help bridge a gap that is 1/4 to 1/2 inches or more wide. There are two standard types of backer rods that are available to use depending upon the installation site.
Asphalt Sealant. Closed cell backer rod or bond breaker tape must be installed at the bottom or base of a dynamically working joint prior to sealant installation to prevent three sided adhesion. Closed cell backer rod diameter should be larger (i.e. typically up to 25% larger) than the actual width of the joint to provide a friction fit
the asphalt pavement. Backer Rod When sealing large cracks, it is impor-tant that the sealant does not drain to the bottom of the crack. To prevent this, sand or backer rods may be placed in the cracks before the placement of the sealant. As seen in Figure 3, using a backer rod when appro-Figure : Hot Air Lance Figure 3. Backer Rod
List Products by Product Name ...
asphalt existing hma backer rod backer rod 2. 4. 1/2 inch paved panel joint seal 1 inch paved panel joint seal 1/2 inch joint seal at end of concrete 1 inch joint seal at end of concrete 1/2 inch concrete asphalt butt joint 1 inch concrete asphalt butt joint joint seals bridge paving d r …
Hot Rod XL backer Rod is a backup material for most hot-pour sealants used to fill contraction and expansion joints of concrete highways, runways, driveways, and parking lots. It's compatible with most rubber-asphalt and coal tar-rubber polymer thermoplastic compounds.
Backer rod is important when sealing large gaps. It allows caulk to span a gap without ripping loose. In the example above backer rod is used where the radon pipe enters the floor before caulk is applied. 1" backer rod is perfect for filling gaps 3/4" to 1-1/8" wide. Sold in 25 foot lengths.
A top supplier of construction supplies for concrete, masonry and road repair; Rebar Tools, Tie Wire, PermaPatch Asphalt Repair, Backer Rod products CALL: (646) 736-7330 or …
TruFlex Rubberized Crack Sealant is designed for filling cracks up to 1" wide in asphalt pavement surfaces. Crack Preparation. Clean all vegetation, dirt, and loose debris from crack. Fill deep cracks with sand or backer rod to within ¾" from pavement surface. …
4. Install Backer Rod: Lightly compress backer-rod into the joint. Install backer-rod using a blunt tool or a plain faced roller. It should form a seal againt edge of joint to prevent sealant from running out. Set the rod to the depth recommended by sealant …
Backer rod is a closed cell rod available in different diameters. Use backer rod for caulking repairs to render, asphalt and timber.
The backer rod comes in three main types, closed cell, open cell, and a hybrid that has closed outer cells but open interior cells. Each one of these types of backer rod has its own niche that it thrives in. Open cell backer rod is great in terms of application, it is very easy to compress and in can even help facilitate the cure of the sealant
Asphalt Crack Backer Rod is designed for the purpose of "pre-filling" cracks in asphalt that are deeper than 1/2″ in depth. The heat-resistant material seals the crack prior to filling the crack with sealant with rubber. Pre-filling the crack with the backer rod saves …
Backer rods are usually round, flexible lengths of that are used as a "backing" in joints or cracks to help control the amount of sealant/caulking used and create a back stop. Many sizes/diameters are available for optimal fitting to the size of the joint being sealed. Besides shape, an important attribute is the variety of cell ...
The backer rod should be non-compressible, non-shrinking, and non-absorbent, and have a higher melting temperature than the asphalt used to fill in the crack. Filling in the crack. After the crack is cleaned and prepared, it's sealed with liquid asphalt.
To install, simply force the BACKER ROD into the crack or joint, cutting to desired length with knife or scissors. Proper position of BACKER ROD in crack is about ½" to ¾" below surface. Then, use NU FLOOR FLEX-JOINT (for concrete) or POURABLE CRACK FILLER (for asphalt) over the BACKER ROD to complete the repair.
Clean the edges of the asphalt with a hand broom and blasts of air or water. Photo 2: Press in backer rod. Stuff backer rod into wide or deep cracks, leaving about 1/2-in. depth to fill with crack filler. The rod conserves filler and makes the repair more flexible. Photo 3: Fill the crack.
The backer rod should be about 25 percent wider than the crack, to prevent slipping or floating out after placing the sealant. After the cracks are prepared, they are sealed with liquid asphalt. Equipment used for crack sealing or filling varies from truck-mounted pressure applicators with hand wands to pour pots.
Came up with a neat trick to make a small backer rod weatherseal fit in a larger gap than the .
Backer Rod is used to partially fill deep expansion joints and cracks before the application of your sealant. It helps prevent 3-sided adhesion while allowing you to control the depth of the sealant. View More. Sakrete 0.5-in x 4-in x 5-ft Polyethylene Concrete Expansion Joints.
Scrub and clean the surface of the repair area with QUIKRETE Concrete and Asphalt Cleaner and a stiff bristle brush. Step 3 Thoroughly rinse the area, after cleaning, and wait for the area to dry, before applying any sealant. Step 4 Once the area is dry, add the backer rod (if needed).
Backer Rod (Hot Rod) Asphalt crack backer rod (also known as "hot rod") is designed for the purpose of pre-filling cracks in asphalt that are deeper than 1/2″ in depth. Backer rod is a continuous-length, compressible material that stops the waste of costly …
Cera-rod. Add to cart or call for pricing: 800-594-0036 – Cincinnati, OH or 800-397-1984 – Markham, IL
Caulk Backer Rod: 20 ft Overall Lg, 5/8 in Overall Wd, 5/8 in Overall Ht, Gray Item # 2RRG2; Mfr. Model # 2RRG2 UNSPSC # 31201606 Catalog Page # N/A Country of Origin USA. Country of Origin is subject to change. Tap image to zoom. Roll over image to zoom. Product Image Feedback ...
faces for the sealer. After cleaning, a backer rod is installed and the joint sealer is applied. The depth of the backer rod and thickness of joint sealer is critical for a properly functioning joint. The depth at which the backer rod is set establishes the bottom of the joint sealer. The depth, and